SCN-500 series

EMC scanners SCN series

Overview

The Pendulum/Detectus series of EMC-Scanners are powerful pre-compliance tools for measurement and analysis of Electro-Magnetic Interference (EMI). The SCN series EMC Scanners with 2D, or 4D scanning feature repetitive high-resolution scanning of emission (and optionally also immunity) down to 0.1 mm steps.

The frequency range is 3, 6 or 10 GHz with the Pendulum near-field probes kits but can be extended by using third-party probe kits. The system has no built-in limitation so if your spectrum analyzer and probes can handle it, you can measure from DC to daylight.

The scanners come in different sizes to accommodate test objects of various sizes. Scanning can be made in 2D, 3D, or even 4D (3D movement plus rotation around the probe axis):

The scan table comes in four basic sizes (WxDxH):
200×100 mm (2D scanning without Z-axis and probe rotation)
200x100x100 mm (4D = 3D scanning with probe rotation)
300x200x100 mm (4D = 3D scanning with probe rotation)
600x400x300 mm (4D = 3D scanning with probe rotation)

The powerful Detectus scanning SW (DSS) is an outstanding easy-to-use scanning SW for control of the scan process, visualization, and documentation of results. The driver library supports hundreds of Spectrum Analyzers, and we continuously add new models from leading manufacturers.

    It's free for anyone to download our software. All you have to do to access our sofware site is to fill out this form.


    Clear selection
    Model
    SCN-500 series
    SCN-500 series
    0.00
    High Resolution 3GHz, 2D EMC scanner system, 200x100mm, 0.1 mm step size. Incl. Near-field Probe set (H-field up to 50 MHz Vertical; H-field 30MHz-3GHz Vertical; H-field 30MHz-3GHz Horizontal; E-field 30MHz-3GHz Vertical) and Preamplifier 30 dB to 3 GHz.
    High Resolution 6GHz, 2D EMC scanner system, 200x100mm, 0.1 mm step size. Incl. Near-field Probe set (H-field up to 50 MHz Vertical; H-field 30MHz-6GHz Vertical; H-field 30MHz-6GHz Horizontal; E-field 30MHz-6GHz Vertical) and Preamplifier 30 dB to 10 GHz.
    High Resolution 3 GHz, 4D scanner system. As SCN-522/3G, plus an axis for Z-movements (100mm height), and rotation of probe
    High Resolution 6 GHz, 4D scanner system. As SCN-522/6G, plus an axis for Z-movements (100mm height), and rotation of probe
    High Resolution 3GHz, 4D EMC scanner system, 300x200x100mm, 0,1 mm step size. Incl. Near-field Probe set (H-field up to 50 MHz Vertical; H-field 30MHz-3GHz Vertical; H-field 30MHz-3GHz Horizontal; E-field 30MHz-3GHz Vertical) and Preamplifier 30 dB to 3 GHz.
    High Resolution 6GHz, 4D EMC scanner system, 300x200x100mm, 0,1 mm step size. Incl. Near-field Probe set (H-field up to 50 MHz Vertical; H-field 30MHz-6GHz Vertical; H-field 30MHz-6GHz Horizontal; E-field 30MHz-6GHz Vertical) and Preamplifier 30 dB to 10 GHz.
    High Resolution 3GHz, 4D EMC scanner system, 600x400x300mm, 0,1 mm step size. Incl. Near-field Probe set (H-field up to 50 MHz Vertical; H-field 30MHz-3GHz Vertical; H-field 30MHz-3GHz Horizontal; E-field 30MHz-3GHz Vertical) and Preamplifier 30 dB to 3 GHz.
    High Resolution 6GHz, 4D EMC scanner system, 600x400x300mm, 0,1 mm step size. Incl. Near-field Probe set (H-field up to 50 MHz Vertical; H-field 30MHz-6GHz Vertical; H-field 30MHz-6GHz Horizontal; E-field 30MHz-6GHz Vertical) and Preamplifier 30 dB to 10 GHz.
    Beacon calibration of probe position for SCN-series only
    "ZR-module for upgrading a SCN-522 EMC-Scanner to a SCN-524. The module adds Z-axis and Rotation, and can be installed by the customer"
    "Z-axis laser distancing meter option for SCN-series 4D-models only. Maintain a constant probe height over the DUT topology, whether high or low components are mounted."
    "Upgrade kit from 3/6 GHz to 10 GHz, for all Scanner families. Incl. Near field Probe set (H-field 1GHz-10GHz Vertical; H-field 1GHz-10GHz Horizontal; E-field 1GHz-10GHz Vertical) and Preamplifier 30 dB; 10MHz to 10 GHz. NOTE: NEW improved Preamplifier"
    Software for immunity measurement. Signal generator to be provided by user.
    Subscription of scanner software updates one year
    Probe calibration option kit. Includes Software + strip line and 50 ohm termination. Tracking generator to be provided by user.
    N male / SMA female adapter
    Two year Extended warranty to a total of 4 years (without product registration, or 5 years (with product registration). Cost: 12% of the order value, where order value = value of basic instrument and built in options.

      Thank you! You have chosen the product available on quotation only. You will receive the sales offer shortly.